37
37
RFSA-11B RFSA-61B RFSA-62B
RFSA-62B
60mm
21mm
1M
RFSA-61B
N
L
N
L
N
L
RFSA-11B
RFSA-61B
RFSA-11B
RFSA-61B
RFSA-62B
RFSA-61B RFSA-62B
Neutral conductor
Supply voltage:
Apparent input:
Dissipated power:
Supply voltage tolerance:
Output
Number of contacts:
Rated current:
Switching power:
Peak current:
Switching voltage:
Max. DC switching power:
Mechanical service life:
Electrical service life (AC1):
Control:
RF, by command from transmitter:
Manual control:
Range in free space:
Other data:
Operating temperature:
Operating position:
Mounting:
Protection:
Overvoltage category:
Contamination degree:
Terminals (CY wire, cross-section):
Length of terminals:
Dimensions:
Weight:
Related standards:
230 V AC / 50 - 60 Hz
7 VA / cos φ = 0.1
0.7 W
+10 %; -15 %
868 MHz
PROG (ON/OFF) button
-15 to + 50 °C
any *
free at lead-in wires
IP 30
III.
2
90 mm
49 x 49 x 21 mm
46 g
EN 60669, EN 300 220, EN 301 489
Directives RTTE,Gov. Reg. No..426/2000Sb(Directives 1999/EC))
Technical parameters
!
!
!
!
!
!
!
!
!
Device description
Functions and their programming
Wiring
The output contact will close by
pressing the button and open by
releasing the button.
The output contact will open by
pressing the button and close after
the set time interval has elapsed.
The output contact will close
by pressing the button.
The output contact will open be
pressing the button.
The output contact will switch to the
opposite position with each press of
the button. If the contact was closed,
it will open and vice versa.
The output contact will close by
pressing the button and open after
the set time interval has elapsed.
Button Switch On
Switch Off
Impulse relay
Delayed return Delayed start
Press 1x Press 2x Press 3x
Press 4x
Press 5x Press 6x
rogram
mode
rogram
mode
rogram
mode
rogram
mode
rogram
mode
rogram
mode
1x switching (AgSnO
2
)
16 A / AC1
4000 VA / AC1, 384 W / DC
30 A / <3 s
250 V AC1 / 24 V DC
500 mW
3x10
7
0.7x10
5
up to 200 m
2x 0.75 mm
2
, 2x 2.5 mm
2
2 x switching (AgSnO
2
)
8 A / AC1
2000 VA / AC1
10 A / <3 s
250 V AC1
500 mW
1x10
7
1x10
5
up to 100 m
1x2.5; 3 x 0.75 mm
2
Phase conductor
RF switching actuators serve to control electrical appliances, lights, heating, garage door, sockets, etc.
switching actuator design
with the 2-channel design of the RFSA-62B multifunction switching actuator, a function can be
programmed for each channel independently
multifunction actuator functions: button, ON/OFF, impulse relay, delayed return, delayed start
for programming and manual control ON/OFF, press the Prog button
RFSA-11B and RFSA-61B switching actuators can be controlled by up to 32 channels, while RFSA-62B
switching actuator can be controlled by 16 channels at 1 relay
possibility to assign receivers to the RF Control system
LED indicator of the device status on the front panel
installation box design (such as KU-68)
CONTROLS ELEMENTS
EAN code
RFSA-11B: 8595188136839 / RFSA-61B: 8595188136242 / RFSA-62B: 8595188142816
Indication of operating
and programming mode
Output relay contacts
Program button (ON/OFF
manual control)
Indication of operating
and programming mode
Program button
(ON/OFF manual control)
Neutral conductor
Phase conductor
Output relay contacts
* For more information, see p. 36
Switching
actuators
RFSA-11B
RFSA-61B
RFSA-62B
Output Rated current Number of functions
Channel 1 Channel 2 16A 8A 1 6
RF receiver: Switching actuators RFSA-11B, RFSA-61B, RFSA-62B